PoolWaterLAB Photometer V2.0
- Developed in Germany for the US market
- Free return within 30 days
- Orders are shipped within 24 hours with 2–3 days delivery. All items are stocked locally in warehouses across the USA for faster shipping. Free Shipping on All U.S. To find out the cost of worldwide shipping, simply add the items to your cart, enter your shipping details, and the cost will be automatically calculated. For now orders to Canada are shipped from Europe and all customs duties will be paid.
- In stock, ready to ship
- Backordered, shipping soon
NOT FOR EVERYONE - PLEASE READ FIRST
If you're looking for a simple, “marketing-style” pool tester with basic strips and minimal setup, this device is not for you. Our photometer is built for users who are ready to move with the times, embrace modern precision technology, and spend a little time learning how the device works. Once you understand the basics, the testing process becomes incredibly easy, fast, and consistently accurate.
A professional-grade photometer designed for precise pool and spa water analysis.
Provides accurate, repeatable digital readings to support confident water chemistry decisions.
ACCURATE - Level 1 (L1): The highest accuracy and repeatability performance level of a water testing device.
Under laboratory conditions, the instrument-/reagent- and user related tolerances can be up to +/- 10 % of the actual value. For the parameter "pH" a tolerance of up to +/- pH 0.10 applies.
- Collect a water sample and place it in the measuring chamber of the PoolWaterLAB photometer.
- Add the reagent to the water sample; the reagent will react with the target chemical compound in the water.
- PoolWaterLAB will measure the concentration of the chemical compound and display the result in ppm.
This page focuses on the typical cost per test when using the PoolWaterLAB® photometer, based on reagent consumption for different pool and spa water parameters.
The table below lists each measured parameter together with its measurement range, typical accuracy, reagent type, and estimated reagent cost per test.
For information about measurement principles and accuracy, see Accuracy & Technology. For explanations of what each parameter represents, see Measured Parameters.
| Parameter | Range ppm (mg/l) | Accuracy L1 | Cost Per Test | Reagent |
|---|---|---|---|---|
| Free Chlorine | 0,00 – 6,00 | ±10% | $0,26 | Tablet/Liquid |
| pH | 6,50 – 8,40 | ±0,10 | $0,26 | Tablet/Liquid |
| Alkalinity | 0 – 200 | ±10% | $0,28 | Tablet/Liquid |
| Calcium Hardness | 0 – 500 | ±10% | $0,68 | Liquid |
| Cyanuric Acid | 0 – 100 | ±10% | $0,32 | Tablet |
| Total Chlorine | 0,00 – 6,00 | ±10% | $0,26 | Tablet/Liquid |
| Phosphate (LR) | 0,00 – 4,00 | ±10% | $0,60 | Powder |
| Iron (LR) | 0,00 – 1,00 | ±10% | $0,51 | Tablet |
| Copper | 0,00 – 5,00 | ±10% | $0,70 | Tablet |
| Nitrate | 0 – 50 | ±10% | $2,40 | Powder |
| Urea | 0,10 – 2,50 | ±10% | $2,55 | Liquid |
| Active Oxygen | 0,00 – 20,0 | ±10% | $0,28 | Tablet |
| Aluminum | 0,00 – 0,30 | ±10% | $0,80 | Tablet |
| Ammonia | 0,00 – 1,20 | ±10% | $0,80 | Powder |
| Bromine | 0,00 – 13,0 | ±10% | $0,26 | Tablet/Liquid |
| Chloramines | 0,00 – 6,00 | ±10% | $0,93 | Tablet |
| Chlorine (HR) | 5 – 200 | ±10% | $0,40 | Powder |
| Chlorine Dioxide | 0,00 – 11,0 | ±10% | $0,26 | Tablet |
| Hydrogen Peroxide (LR) | 0,00 – 2,40 | ±10% | $0,40 | Tablet |
| Hydrogen Peroxide (HR) | 0 – 180 | ±10% | $0,40 | Tablet |
| Nitrite (LR) | 0,00 – 1,50 | ±10% | $0,50 | Powder |
| Ozone | 0,00 – 4,00 | ±10% | $0,52 | Tablet/Liquid |
| PHMB | 5 – 60 | ±10% | $0,40 | Tablet |
| Phosphate (HR) | 0 – 80 | ±10% | $0,80 | Powder |
| Potassium | 0,70 – 12,0 | ±10% | $0,80 | Tablet |
| Sulfate | 5 – 100 | ±10% | $0,52 | Powder |
| Total Hardness | 0 – 500 | ±10% | $0,70 | Liquid |
| Zinc | 0,00 – 1,00 | ±10% | $1,30 | Tablet |
| Parameter | Fresh water | Saltwater | Seawater |
|---|---|---|---|
| Active oxygen | ✔ | ✔ | |
| Alkalinity | ✔ | ✔ | ✔ |
| Bromine | ✔ | ✔ | |
| Chlorine | ✔ | ✔ | |
| Chlorine dioxide | ✔ | ✔ | |
| Cyanuric acid | ✔ | ✔ | |
| Total hardness | ✔ | ||
| Calcium hardness | ✔ | ✔ | |
| Ozone | ✔ | ✔ | |
| pH | ✔ | ✔ * | |
| Hydrogen peroxide | ✔ | ✔ |
* Special case pH measurement
Depending on the salt content of your sample, the measurement result must be corrected according to the following scheme:
1 molar = -0,21 pH
2 molar = -0,26 pH
3 molar = -0,29 pH
where: 1 mol salt (NaCl) = 5.8 % = 58.4 g/l
Pools with salt electrolysis are not affected.
In salt electrolysis, a maximum of 7 g/l salt is used, far less than 1 mol (58.4 g).
1 x PoolWaterLAB (Water Tester)
1 x Triple measurement cuvette (exchangeable)
1 x Light protection cap
3 x Plastic special stirring stick
1 x 10ml syringe
1 x Water Leveler
3 x AA batteries
1 x Digital user manual
1 x Blue bag
20 tablets DPD N 1 (free chlorine)
20 tablets Phenol Red (pH)
10 tablets DPD N 3 (combined / total chlorine)
10 tablets CYA test (cyanuric acid / stabilizer)
10 tablets Alkalinity-M (alkalinity / acid capacity)
LabCOM Software
LabCOM App
LabCOM Cloud Service
24 month warranty